PA-840-352R-R2

Description :
PRESSURE TRANSDUCER DIFFERENTIAL
Forfait :
Module
Accuracy :
±0.5%
Features :
Temperature Compensated
Maximum Pressure :
101.53 PSI (700 kPa)
Operating Pressure :
-14.5 ~ 50.76 PSI (-100 ~ 350 kPa)
Operating Temperature :
-20°C ~ 100°C
Output :
1 V ~ 5 V
Output Type :
Analog Voltage
Package / Case :
Module
Port Size :
Male - M5,Male - 1/4" (6.35mm) NPT
Port Style :
Threaded
Pressure Type :
Compound
Series :
PA-840
Supplier Device Package :
Module
Termination Style :
Cable
Voltage - Supply :
10.8 V ~ 26.4 V