- Series:
-
- Voltage - Supply:
-
- Operating Temperature:
-
- Mounting Type:
-
- Frequency:
-
- Response Time:
-
- Sensor Type:
-
- Accuracy:
-
- Linearity:
-
- Polarization:
-
- Conditions sélectionnées:
Découvrez les produits 16
Image | Numéro de pièce | Fabricant | Quantité | Délai de livraison | Prix unitaire | Acheter | Description | Series | Voltage - Supply | Operating Temperature | Output | Mounting Type | Frequency | Response Time | Sensor Type | Accuracy | Linearity | Polarization | For Measuring | Current - Sensing | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Image | Numéro de pièce | Fabricant | Quantité | Délai de livraison | Prix unitaire | Acheter | Description | Series | Voltage - Supply | Operating Temperature | Output | Mounting Type | Frequency | Response Time | Sensor Type | Accuracy | Linearity | Polarization | For Measuring | Current - Sensing | ||
Phoenix Contact |
11
|
3 jours |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 55A AC/DC
|
- | 20 V ~ 30 V | -20°C ~ 60°C | Ratiometric,Voltage and Current | DIN Rail | 15Hz ~ 400Hz | 330ms (AC),40ms (DC) | Hall Effect,Open Loop | ±0.5% | - | Bidirectional | AC/DC | 55A | ||||
Tamura |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 100A AC/DC
|
- | ±12 V ~ 15 V | -40°C ~ 85°C | Ratiometric,Current | Through Hole | DC ~ 100kHz | 0.5μs | Hall Effect,Closed Loop | ±0.25% | ±0.15% | Bidirectional | AC/DC | 100A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 200A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 200A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 75A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 75A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 50A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 50A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 100A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 100A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 150A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 150A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 20A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 20A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 300A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 300A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 40A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 40A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 30A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Hall Effect,Closed Loop | ±1% | - | Unidirectional | DC | 30A | ||||
Phoenix Contact |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 11A AC/DC
|
- | 20 V ~ 30 V | -20°C ~ 60°C | Ratiometric,Voltage and Current | DIN Rail | 15Hz ~ 400Hz | 330ms (AC),40ms (DC) | Hall Effect,Open Loop | ±0.5% | - | Bidirectional | AC/DC | 11A | ||||
Phoenix Contact |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT HALL 55A AC/DC
|
- | 20 V ~ 30 V | -20°C ~ 60°C | Ratiometric,Voltage and Current | DIN Rail | 15Hz ~ 400Hz | 330ms (AC),40ms (DC) | Hall Effect,Open Loop | ±0.5% | - | Bidirectional | AC/DC | 55A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT MAGNETIC 10A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Magnetic Modulator,Closed Loop | ±1% | - | Unidirectional | DC | 10A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT MAGNETIC 5A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Magnetic Modulator,Closed Loop | ±1% | - | Unidirectional | DC | 5A | ||||
CR Magnetics Inc. |
Enquête
|
- |
-
|
MOQ: 1 MPQ: 1
|
SENSOR CURRENT MAGNETIC 2A DC
|
CR5200 | 24V | 0°C ~ 50°C | Ratiometric,4mA ~ 20mA | DIN Rail,Panel | DC | 250ms | Magnetic Modulator,Closed Loop | ±1% | - | Unidirectional | DC | 2A |